5 Adjustments

5.8.1 Switching Gain Settings

5-54

(2) Manual Gain Switching

Manual gain switching uses G-SEL of the servo command output signals (SVCMD_IO) to switch between

gain setting 1 and gain setting 2.

(3) Automatic Gain Switching

Automatic gain switching is enabled only in position control. The switching conditions are specified using the

following settings.

Select one of the following settings for switching condition A.

Type

Command Name

Setting

Meaning

Input

G-SEL of the servo com-
mand output signals

(SVCMD_IO)

0

Switches to gain setting 1.

1

Switches to gain setting 2.

Parameter Setting

Switching Condition

Setting

Switching Wait

Time

Switching Time

Pn139

n.

2

Condition A satisfied.

Gain setting 1 to
gain setting 2

Pn135

Gain Switching
Waiting Time 1

Pn131

Gain Switching
Time 1

Condition A not satisfied.

Gain setting 2 to
gain setting 1

Pn136
Gain Switching
Waiting Time 2

Pn132
Gain Switching
Time 2

Parameter

Switching Condition A

for Position Control

For Other than Posi-

tion Control (No

Switching)

When

Enabled

Classification

Pn139

n.

0

[Factory setting]

Positioning completed
signal (/COIN) ON

Fixed in gain setting 1

Immediately

Tuning

n.

1

Positioning completed
signal (/COIN) OFF

Fixed in gain setting 2

n.

2

Positioning near signal
(/NEAR) ON

Fixed in gain setting 1

n.

3

Positioning near signal
(/NEAR) OFF

Fixed in gain setting 2

n.

4

No output for position
reference filter and posi-
tion reference input OFF

Fixed in gain setting 1

n.

5

Position reference input
ON

Fixed in gain setting 2

Gain

Settings 2

Pn104
Pn105
Pn106
Pn122
Pn412

Condition A

satisfied

Condition A
not satisfied

Switching Waiting Time 1 Pn135

Switching Time 1 Pn131

Switching Waiting Time 2

ޓPn136

Switching Time 2

ޓPn132

Gain

Settings 1

Pn100
Pn101
Pn102
Pn121
Pn401

Automatic switching pattern 1 (Pn139.0 = 2)