Yaskawa Sigma-5 User Manual: Design and Maintenance - Linear Motors MECHATROLINK-III Communications Reference User Manual

Page 336

Advertising
background image

9 Appendix

9.1.3 MECHATROLINK-III Common Parameters

9-38

21

PnA42

4

Electronic Gear Ratio (Numerator)

1 to

1073741824

1

After

restart

Machine

Specification

Related

Parameters

22

PnA44

4

Electronic Gear Ratio (Denomina-
tor)

1 to

1073741824

1

After

restart

23

PnA46

4

Absolute Encoder Origin Offset

–1073741823

to 1073741823

1 reference unit

0

Immedi-

ately

*2

25

PnA4A

4

Limit Setting

0 to 33H

0000H

0000H

After

restart

Bit 0

P-OT (0: Enabled, 1: Disabled)

Bit 1

N-OT (0: Enabled, 1: Disabled)

Bit 2

Reserved

Bit 3

Reserved

Bit 4

P-SOT (0: Disabled, 1: Enabled)

Bit 5

N-SOT (0: Disabled, 1: Enabled)

Bit 6

Reserved

Bit
7 to 31

Reserved

26

PnA4C

4

Forward Software Limit

–1073741823

to

1073741823

1 reference unit

1073741823

Immedi-

ately

27

PnA4E

4

Reserved (Do not use.)

0

Immedi-

ately

28

PnA50

4

Reverse Software Limit

–1073741823

to

1073741823

1 reference unit

–1073741823

Immedi-

ately

29

PnA52

4

Reserved (Do not use.)

0

Immedi-

ately

41
PnA82

4

Speed Unit

0 to 4

0

After

restart

Unit System

Related

Parameters

0000H

reference unit/sec

0001H

reference unit/min

0002H

Percentage (%) of rated speed

*3

0003H

mm/s

*3

0004H

Max. motor speed/40000000H

*4

42

PnA84

4

Speed Base Unit
(Set the value of “n” used as the
exponent in 10

n

when calculating

the Speed Unit (41).)

*3*4

–3 to 3

0

After

restart

43

PnA86

4

Position Unit

0

0

After

restart

0000H

reference unit

44

PnA88

4

Position Base Unit
(Set the value of “n” used as the
exponent in 10

n

when calculating

the Position Unit (43).)

0

0

After

restart

∗2. Available after the SENS_ON command is input.

∗3. When either 0002H or 0003H is selected for the Speed Unit (parameter 41), set the Speed Base Unit (parameter 42)

to a number between -3 and 0.

∗4. When 0004H is selected for the Speed Unit (parameter 41), set the Speed Base Unit (parameter 42) to 0.

Note: When using parameters that are enabled after restarting the SERVOPACK, a CONFIG command must be input or

the power must be turned OFF and then ON again.

(cont’d)

Parameter

No.

Size

Name

Setting Range

Units

[Resolution]

Factory

Setting

When

Enabled

Classifica-

tion

Advertising