Yaskawa Sigma-5 User Manual: Design and Maintenance - Linear Motors MECHATROLINK-III Communications Reference User Manual

Page 331

Advertising
background image

9.1 List of Parameters

9-33

9

Ap

pend

ix

Pn860

2

SVCMD_IO (input signal
monitor) Allocation 1

0000 to 1717

0000

Immediately

Setup

M3

*9

Pn861

2

SVCMD_IO (input signal
monitor) Allocation 2

0000 to 1717

0000

Immediately

Setup

M3

*9

Pn862

2

SVCMD_IO (input signal
monitor) Allocation 3

0000 to 1717

0000

Immediately

Setup

M3

*9

∗9. This parameter is enabled only for MECHATROLINK-III standard servo profile.

(cont’d)

Parameter

No.

Size

Name

Setting

Range

Units

Factory

Setting

When

Enabled

Classi-

fication

Profile

Reference

Section

0 to 7

Bit position of CN1-13 input terminal monitor

0

Disables bit allocation for CN1-13 input terminal monitor.

1

Enables bit allocation for CN1-13 input terminal monitor.

0 to 7

Bit position of CN1-7 input terminal monitor

0

Disables bit allocation for CN1-7 input terminal monitor.

1

Enables bit allocation for CN1-7 input terminal monitor.

4th 3rd 2nd 1st

digit digit digit digit

n.

0 to 7

Bit position of CN1-8 input terminal monitor

0

Disables bit allocation for CN1-8 input terminal monitor.

1

Enables bit allocation for CN1-8 input terminal monitor.

0 to 7

Bit position of CN1-9 input terminal monitor

0

Disables bit allocation for CN1-9 input terminal monitor.

1

Enables bit allocation for CN1-9 input terminal monitor.

4th 3rd 2nd 1st

digit digit digit digit

n.

0 to 7

Bit position of CN1-10 input terminal monitor

0

Disables bit allocation for CN1-10 input terminal monitor.

1

Enables bit allocation for CN1-10 input terminal monitor.

0 to 7

Bit position of CN1-11 input terminal monitor

0

Disables bit allocation for CN1-11 input terminal monitor.

1

Enables bit allocation for CN1-11 input terminal monitor.

4th 3rd 2nd 1st

digit digit digit digit

n.

Advertising