Yaskawa Sigma-5 User Manual: Design and Maintenance - Linear Motors MECHATROLINK-III Communications Reference User Manual

Page 312

Advertising
background image

9 Appendix

9.1.2 Parameters

9-14

Pn404

2

Forward External Force Limit

0 to 800

1%

100

Immediately

Setup

4.6.2

Pn405

2

Reverse External Force Limit

0 to 800

1%

100

Immediately

Setup

Pn406

2

Emergency Stop Force

0 to 800

1%

800

Immediately

Setup

4.3.2

Pn408

2

Force Related Function

Switch

0000 to 1111

0000

Pn409

2

1st Notch Filter Frequency

50 to 5000

1 Hz

5000

Immediately

Tuning

5.9.3

Pn40A

2

1st Notch Filter Q Value

50 to 1000

0.01

70

Immediately

Tuning

Pn40B

2

1st Notch Filter Depth

0 to 1000

0.001

0

Immediately

Tuning

Pn40C

2

2nd Notch Filter Frequency

50 to 5000

1 Hz

5000

Immediately

Tuning

Pn40D

2

2nd Notch Filter Q Value

50 to 1000

0.01

70

Immediately

Tuning

Pn40E

2

2nd Notch Filter Depth

0 to 1000

0.001

0

Immediately

Tuning

Pn40F

2

2nd Step 2nd Force Reference
Filter Frequency

100 to 5000

1 Hz

5000

Immediately

Tuning

Pn410

2

2nd Step 2nd Force Reference
Filter Q Value

50 to 100

0.01

50

Immediately

Tuning

Pn412

2

1st Step 2nd Force Reference
Filter Time Constant

0 to 65535

0.01 ms

100

Immediately

Tuning

5.8.1

Pn415

2

Reserved (Do not change.)

0

Pn423

2

Reserved (Do not change.)

0000

Pn424

2

Force Limit at Main Circuit
Voltage Drop

0 to 100

1%

50

Immediately

Setup

4.3.8

Pn425

2

Release Time for Force Limit
at Main Circuit Voltage Drop

0 to 1000

1 ms

100

Immediately

Setup

Pn456

2

Sweep Force Reference
Amplitude

1 to 800

1%

15

Immediately

Tuning

6.21

(cont’d)

Parameter

No.

Size

Name

Setting

Range

Units

Factory

Setting

When

Enabled

Classi-

fication

Profile

Reference

Section

1st Step Notch Filter Selection

When

Enabled

Classification

Reference

Section

0

N/A

Immediately

Setup

5.9.3

1

Uses 1st step notch filter for force reference.

Speed Limit Selection

When

Enabled

Classification

Reference

Section

0

Uses the smaller of the maximum motor speed and
the value of Pn480 as the speed limit value.

After restart

Setup

4.8.8

1

Uses the smaller of the overspeed detection speed
and the value of Pn480 as the speed limit value.

2nd Step Notch Filter Selection

When

Enabled

Classification

Reference

Section

0

N/A

Immediately

Setup

5.9.3

1

Uses 2nd step notch filter for force reference.

Friction Compensation Function Selection

When

Enabled

Classification

Reference

Section

0

Disables friction compensation function.

Immediately

Setup

5.8.2

1

Enables friction compensation function.

4th 3rd 2nd 1st

digit digit digit digit

n.

Advertising