3.4 Examples of Connection to Host Controller

3-23

3

Wirin

g and

Co

nnectio

n

3.4 Examples of Connection to Host Controller

This section shows examples of SERVOPACK I/O signal connection to the host controller.

3.4.1 Sequence Input Circuit

(1) Photocoupler Input Circuit

CN1 connector terminals 6 to 13 are explained below.

The sequence input circuit interface is connected through a relay or open-collector transistor circuit. When
connecting through a relay, use a low-current relay. If a low-current relay is not used, a faulty contact may

result.

Note: The 24 VDC external power supply capacity must be 50 mA minimum.

The SERVOPACK’s input circuit uses bidirectional photocoupler. Select either the sink circuit or the source
circuit according to the specifications required for each machine.

Note:

The connection example in 3.2.3 shows sink circuits.

• The ON/OFF polarity differs between when a sink circuit is connected and when a source circuit is connected.

Relay Circuit Example

Open-collector Circuit Example

Sink Circuit

Source Circuit

Input Signal Polarities

Input Signal Polarities

Signal

Level

Voltage

Level

Contact

Signal

Level

Voltage

Level

Contact

ON

Low (L)

level

0 V

Close

ON

High (H)

level

24 V

Close

OFF

High (H)

level

24 V

Open

OFF

Low (L)

level

0 V

Open

3.3 k

Ω

/DEC, etc.

SERVOPACK

24 VDC

+24 VIN

24 VDC

3.3 k

Ω

/DEC, etc.

SERVOPACK

+24 VIN

24 V

+

SERVOPACK input

24 V

+

SERVOPACK input