2) operating procedure, 3) related parameters – Yaskawa Sigma-5 User Manual: Design and Maintenance - Linear Motors MECHATROLINK-III Communications Reference User Manual

Page 242

Advertising
background image

6.16 Vibration Detection Level Initialization (Fn01B)

6-27

6

Utili

ty Fu

ncti

ons (Fn

)

(2) Operating Procedure

Use the following procedure.

(3) Related Parameters

The following table lists parameters related to this function and their possibility of being changed while exe-

cuting this function or of being changed automatically after executing this function.

• Parameters related to this function

These are parameters that are used or referenced when executing this function.

• Allowed changes during execution of this function

Yes : Parameters can be changed using SigmaWin+ while this function is being executed.

No : Parameters cannot be changed using SigmaWin+ while this function is being executed.

• Automatic changes after execution of this function

Yes : Parameter set values are automatically set or adjusted after execution of this function.
No : Parameter set values are not automatically set or adjusted after execution of this function.

Step

Display after Operation

Keys

Operation

1

Press the

Key to view the main menu for the

utility function.
Use the

or

Key to move through the list and

select Fn01B.

2

Press the

Key. The display changes to the Fn01B

execution display.

3

Press the

Key.

"Init" is displayed flashing, and the vibration level is
detected and initialized.
Note: Continues initialization until the

Key is

pressed again.

4

Press the

Key. The display changes from "Init"

to "DONE," for one second and the new setting of
Pn384 becomes enabled.

5

Press the

Key. The display returns to the main

menu of the utility function.

R U N

− F U N C T I O N −

F n 0 1 4 : O p t I n i t
F n 0 1 B : V i b l v l I n i t
F n 0 1 E : S v M o t O p I D
F n 0 2 0 : S

− O r i g S e t

48
and
65

R U N
V i b r a t i o n D e t e c t
L e v e l I n i t
S t a r t : [ D A T A ]
R e t u r n : [ S E T ]

R U N
V i b r a t i o n D e t e c t
L e v e l I n i t

I n i t

R U N
V i b r a t i o n D e t e c t
L e v e l I n i t

D

㧻 㧺 㧱

R U N

− F U N C T I O N −

F n 0 1 4 : O p t I n i t
F n 0 1 B : V i b l v l I n i t
F n 0 1 E : S v M o t O p I D
F n 0 2 0 : S

− O r i g S e t

48 and 65

Parameter

Name

Mid-execution

changes

Automatic

changes

Pn311

Vibration Detection Sensitivity

Yes

No

Pn384

Vibration Detection Level

No

Yes