2 warning displays, 1 list of warnings – Yaskawa Sigma-5 User Manual: Design and Maintenance - Linear Motors MECHATROLINK-III Communications Reference User Manual

Page 285

Advertising
background image

8 Troubleshooting

8.2.1 List of Warnings

8-24

8.2 Warning Displays

The following sections describe troubleshooting in response to warning displays.

The warning name and warning meaning output are listed in order of the warning numbers in 8.2.1 List of
Warnings
.

The causes of warnings and troubleshooting methods are provided in 8.2.2 Troubleshooting of Warnings.

8.2.1 List of Warnings

This section provides list of warnings.

Warning

Number

Warning Name

Meaning

Reset

A.900

*1

Position Error Overflow

Position error exceeded the parameter setting

(Pn520

×Pn51E/100).

Required

A.901

*1

Position Error Overflow

Alarm at Servo ON

When the servomotor power is ON, the position error exceeded
the parameter setting (Pn526

×Pn528/100).

Required

A.910

*1

Overload

This warning occurs before the overload alarms (A.710 or
A.720) occur. If the warning is ignored and operation contin-
ues, an overload alarm may occur.

Required

A.911

*1

Vibration

Abnormal vibration at the motor speed was detected. The
detection level is the same as A.520. Set whether to output an
alarm or warning by the vibration detection switch (Pn310).

Required

A.920

*1

Regenerative Overload

This warning occurs before the regenerative overload alarm
(A.320) occurs. If the warning is ignored and operation contin-
ues, a regenerative overload alarm may occur.

Required

A.921

*1

Dynamic Brake Overload

This warning occurs before dynamic brake overload alarm
(A.731) occurs. If the warning is ignored and operation contin-
ues, a dynamic brake overload alarm may occur.

Required

A.94A

*2

Data Setting Warning 1

(Parameter Number Error) Incorrect command parameter number was set.

Automatic
reset

*4

A.94B

*2

Data Setting Warning 2

(Out of Range)

Command input data is out of range.

Automatic
reset

*4

A.94C

*2

Data Setting Warning 3

(Calculation Error)

Calculation error was detected.

Automatic
reset

*4

A.94D

*2

Data Setting Warning 4

(Parameter Size)

Data size does not match.

Automatic
reset

*4

A.94E

*2

Data Setting Warning 5

(Latch Mode Error)

Latch mode error is detected.

Required

A.95A

*2

Command Warning 1

(Unsatisfying Command)

Command was sent although the conditions for sending a com-
mand were not satisfied.

Automatic
reset

*4

A.95B

*2

Command Warning 2

(Non-supported Com-

mand)

Unsupported command was sent.

Automatic
reset

*4

A.95D

*2

Command Warning 4

(Command Interference)

Command, especially latch command, interferes.

Automatic
reset

*4

A.95E

*2

Command Warning 5

(Subcommand Disable)

Subcommand and main command interfere.

Automatic
reset

*4

A.95F

*2

Command Warning 6

(Undefined Command)

Undefined command was sent.

Automatic
reset

*4

A.960

*2

MECHATROLINK
Communications Warning

Communications error occurred during MECHATROLINK

communications.

Required

A.962

*2

MECHATROLINK

Communications Warning

(FCS Error)

Communications error occurred during MECHATROLINK

communications.

Required

Advertising