6.22 Online Vibration Monitor (Fn207)

6-37

6

Utili

ty Fu

ncti

ons (Fn

)

6.22 Online Vibration Monitor (Fn207)

If vibration is generated during operation and this function is executed while the servomotor power is still ON,

the machine vibration can sometimes be suppressed by setting a notch filter or force reference filter for the

vibration frequencies.

When online, vibration frequency caused by machine resonance will be detected and the frequency that has

the highest peak will be displayed on the panel operator. The effective force reference filter or notch filter fre-
quency for the vibration frequencies will be automatically selected and the related parameters will be automat-

ically set.

In addition to this function, EasyFFT (Fn206) can be used to detect machine vibration and automatically make

notch filter settings. Use the following flowchart to determine how these functions should be used.

If a

Σ-V Series SERVOPACK is used to make adjustments, it is recommended that you use advanced autotun-

ing. This built-in function is used to maintain interchangeability with previous models. There is normally no

need to use it.

(1) Preparation

The following conditions must be met to perform online vibration monitoring.

• The write prohibited setting parameter (Fn010) must be set to Write permitted (P.0000).
• The servomotor power must be ON.
• There must be no overtravel.
• The correct mass (Pn103) must be set.
• The test without a motor function must be disabled (Pn00C.0 = 0).

Start

How to use EasyFFT (Fn206) and online vibration monitor (Fn207),
when they are mainly used for servo gain adjustment.

End

Vibration with

high-frequency noise

during operation

No

No

Yes

Yes

Adjust servo gain

Vibration

With the servomotor power ON,
execute online vibration
monitor (Fn207)

Turn OFF the servomotor power,
and execute EasyFFT (Fn206)

Advertising