9 Appendix

9.1.2 Parameters

9-16

Pn50A

2

Input Signal Selection 1

0000 to

FFF1

1881

After restart

Setup

(cont’d)

Parameter

No.

Size

Name

Setting

Range

Units

Factory

Setting

When

Enabled

Classi-

fication

Profile

Reference

Section

Reserved (Do not change.)

Reserved (Do not change.)

Reserved (Do not change.)

P-OT Signal Mapping (Forward run prohibited when OFF (open))

Reference

Section

0

Forward run allowed when CN1-13 input signal is ON (closed).

4.3.2

1

Forward run allowed when CN1-7 input signal is ON (closed).

2

Forward run allowed when CN1-8 input signal is ON (closed).

3

Forward run allowed when CN1-9 input signal is ON (closed).

4

Forward run allowed when CN1-10 input signal is ON (closed).

5

Forward run allowed when CN1-11 input signal is ON (closed).

6

Forward run allowed when CN1-12 input signal is ON (closed).

7

Forward run prohibited.

8

Forward run allowed.

9

Forward run allowed when CN1-13 input signal is OFF (open).

A

Forward run allowed when CN1-7 input signal is OFF (open).

B

Forward run allowed when CN1-8 input signal is OFF (open).

C

Forward run allowed when CN1-9 input signal is OFF (open).

D

Forward run allowed when CN1-10 input signal is OFF (open).

E

Forward run allowed when CN1-11 input signal is OFF (open).

F

Forward run allowed when CN1-12 input signal is OFF (open).

4th 3rd 2nd 1st

digit digit digit digit

n.