Yaskawa Sigma-5 User Manual: Design and Maintenance - Linear Motors MECHATROLINK-III Communications Reference User Manual

Page 350

Advertising
background image

9 Appendix

9-52

Pn883

0

Communications Cycle Setting
Monitor [x transmission cycle]
(for maintenance, read only)

Immediately

Pn884

0000

Communications Controls 2

Immediately

Pn88A

0

MECHATROLINK Receive Error
Counter Monitor
(for maintenance, read only)

Immediately

Pn890 to

Pn8A6

0

Command Data Monitor at Alarm/
Warning Occurs
(for maintenance, read only)

Immediately

Pn8A8 to

Pn8BE

0

Response Data Monitor at Alarm/
Warning Occurs
(for maintenance, read only)

Immediately

Pn900

0

Parameter Bank Number

After restart

Pn901

0

Parameter Bank Member Number

After restart

Pn902 to

Pn910

0

Parameter Bank Member Definition

After restart

Pn920 to

Pn95F

0

Parameter Bank Data (nonvolatile
memory save disabled)

Immediately

01
PnA02

Encoder Type (read only)

02
PnA04

Motor Type (read only)

03
PnA06

Semi-closed/Fully-closed Type (read
only

04
PnA08

Rated Speed (read only)

05

PnA0A

Maximum Output Speed (read only)

06
PnA0C

Speed Multiplier (read only)

07
PnA0E

Rated Force (read only)

08
PnA10

Maximum Output Force (read only)

09
PnA12

Force Multiplier (read only)

0B
PnA16

0

Scale Pitch

After restart

0C
PnA18

Pulses per Scale Pitch (read only)

21
PnA42

1

Electronic Gear Ratio (Numerator)

After restart

22
PnA44

1

Electronic Gear Ratio (Denominator)

After restart

23
PnA46

0

Absolute Encoder Origin Offset

Immedi-

ately

∗1

25
PnA4A

0000H

Limit Setting

After restart

∗1. Available after the SENS_ON command is input.

Note: When using parameters that are enabled after restarting the SERVOPACK, a CONFIG command must be input or

the power must be turned OFF and then ON again.

(cont’d)

Parameter

Factory

Setting

Name

When

Enabled

Advertising