9 Appendix

9.1.3 MECHATROLINK-III Common Parameters

9-40

61

PnAC2

4

Speed Loop Gain

1000 to

2000000

0.001 Hz

[0.1 Hz]

40000

Immedi-

ately

Adjustment

Related

Parameters

62

PnAC4

4

Speed Loop Integral Time Constant

150 to 512000

μs

[0.01 ms]

20000

Immedi-

ately

63

PnAC6

4

Position Loop Gain

1000 to

2000000

0.001/s

[0.1/s]

40000

Immedi-

ately

64

PnAC8

4

Feedforward Compensation

0 to 100

1%

0

Immedi-

ately

65

PnACA

4

Position Loop Integral Time Con-
stant

0 to 5000000

μs

[0.1 ms]

0

Immedi-

ately

66

PnACC

4

Positioning Completed Width

0 to

1073741824

1 reference unit

7

Immedi-

ately

67

PnACE

4

NEAR Signal Width

1 to

1073741824

1 reference unit

1073741824

Immedi-

ately

81

PnB02

4

Exponential Function Accel/Decel
Time Constant

0 to 510000

μs

[0.1 ms]

0

Immedi-

ately

*6

82

PnB04

4

Movement Average Time

0 to 510000

μs

[0.1 ms]

0

Immedi-

ately

*6

83

PnB06

4

Final Travel Distance for External
Positioning

–1073741823

to 1073741823

1 reference unit

100

Immedi-

ately

84

PnB08

4

Homing Approach Speed

0 to

3FFFFFFFH

10

-3

mm/s

5000

Value

converted

reference/s

into 10

-3

mm/s

Immedi-

ately

85

PnB0A

4

Homing Creep Speed

0 to

3FFFFFFFH

10

-3

mm/s

500

Value

converted

reference/s

into 10

-3

mm/s

Immedi-

ately

86

PnB0C

4

Final Travel Distance for Homing

–1073741823

to 1073741823

1 reference unit

100

Immedi-

ately

87

PnB0E

4

Monitor Selection 1

0 to F

1

Immedi-

ately

0000H

APOS

0001H

CPOS

0002H

PERR

0003H

LPOS1

0004H

LPOS2

0005H

FSPD

0006H

CSPD

0007H

TRQ

0008H

ALARM

0009H

MPOS

000AH

Reserved (Undefined value)

000BH

Reserved (Undefined value)

000CH

CMN1 (Common monitor 1)

000DH

CMN2 (Common monitor 2)

000EH

OMN1 (Optional monitor 1)

000FH

OMN2 (Optional monitor 2)