8.2 Warning Displays

8-29

8

Trou

blesh

ooting

A.963
MECHATROLINK
Communica-

tions Warning
(Synchronization
Frame Not
Received)

MECHATROLINK

wiring is incorrect.

Confirm the wiring.

Correct the MECHATROLINK wir-
ing.

Or, connect a terminal to the terminal
station.

MECHATROLINK

data reception error
occurred due to noise
interference.

Confirm the installation conditions.

Take measures against noise. Check
the MECHATROLINK communica-

tions cable and FG wiring and take
measures such as adding ferrite core
on the MECHATROLINK communi-

cations cable.

A SERVOPACK fault
occurred.

A fault occurred in the SERVOPACK.
Replace the SERVOPACK.

A.971:

Undervoltage

• For 100 VAC SER-

VOPACKs:
The AC power supply
voltage is 60 V or
less.

• For 200-VAC SER-

VOPACKs:
The AC power supply
voltage is 140 V or
less.

• For 400-VAC SER-

VOPACKs:
The AC power supply
voltage is 280 V or
less.

Measure the power supply voltage.

Set the power supply voltage within
the specified range.

The power supply volt-
age dropped during
operation.

Measure the power supply voltage.

Increase the power supply capacity.

Occurrence of instanta-
neous power interrup-
tion.

Measure the power supply voltage.

When the instantaneous power cut
hold time (Pn509) is set, decrease the
setting.

The SERVOPACK fuse
is blown out.

Replace the SERVOPACK and con-
nect a reactor to the SERVOPACK.

A SERVOPACK fault
occurred.

The SERVOPACK may be faulty.
Replace the SERVOPACK.

A.97A
Command

Warning 7
(Phase Error)

A command that cannot
be executed in the cur-
rent phase was sent.

Send a command after command
sending condition is satisfied.

A.97B
Data Clamp
(Out Of Range)

The set command data
was clamped to a mini-
mum or maximum

value out of the allow-
able setting range.

Set the value of the command data
within the allowable range.

(cont’d)

Warning Num-

ber: Warning

Name (Warning

Description)

Cause

Investigative Actions

Corrective Actions