13 three-phase 400 v, sgdv-260d25a model, M-iii – Yaskawa Sigma-5 User Manual: Design and Maintenance - Linear Motors MECHATROLINK-III Communications Reference User Manual

Page 35

Advertising
background image

1 Outline

1.4.13 Three-phase 400 V, SGDV-260D25A Model

1-14

1.4.13 Three-phase 400 V, SGDV-260D25A Model

L1

B1/ B2

L2

L3

1
2

+24 V

0 V

U

V

W

ENC

M

CHARGE

+15 V

× 4

±12 V

+5 V

+24 V +24 V +24 V

Current

sensor

Dynamic
brake circuit

Servomotor

Gate

drive

Voltage

sensor

Voltage

sensor

Varistor

Relay

drive

Control
power
supply

Overheat protector,

overcurrent protector

Fan 1

Fan 2

Fan 3

+

+

+

Main circuit
power supply

Control power
supply

(The 24 VDC
power supply is
not included.)

CN3

CN7

CN8

CN2

I/O

I/F

CN1

CN6A

CN6B

CN5

MECHATROLINK-

III

communications

CPU

(Position/speed

calculation, etc.)

Panel display

Digital operator

Personal
computer

Signal for safety fuction

Encoder output
pulse

Analog monitor
output

ASIC

(PWM control, etc.)

Analog

voltage

converter

I/O signal

M-III

Advertising