8.3 Monitoring Communication Data on Occurrence of an Alarm or Warning

8-31

8

Trou

blesh

ooting

8.3 Monitoring Communication Data on Occurrence of an Alarm or

Warning

The command data received on occurrence of an alarm or warning, such as a data setting warning (A.94 ) or

a command warning (A.95 ) can be monitored using the following parameters. The following is an example
of the data when an alarm/warning has occurred in the normal state.

Command Data Monitor at Alarm/Warning Occurrence: Pn890 to Pn8A6
Response Data Monitor at Alarm/Warning Occurrence: Pn8A8 to Pn8BE

Note 1. Data is stored in little endian byte order and displayed in the hexadecimal format.

2. For details on commands, refer to

Σ

-V Series User’s Manual, MECHATROLINK-III Standard Servo Pro-

file Commands (No.: SIEP S800000 63)

Command

Byte Order

Command Data Storage at

Alarm/Warning Occurrence

CMD

RSP

0

Pn890.1 to 0

Pn8A8.1 to 0

1

Pn890.3 to 2

Pn8A8.3 to 2

2

Pn890.5 to 4

Pn8A8.5 to 4

3

Pn890.7 to 6

Pn8A8.7 to 6

4 to 7

Pn892

Pn8AA

8 to 11

Pn894

Pn8AC

12 to 15

Pn896

Pn8AE

16 to 19

Pn898

Pn8B0

20 to 23

Pn89A

Pn8B2

24 to 27

Pn89C

Pn8B4

28 to 31

Pn89E

Pn8B6

32 to 35

Pn8A0

Pn8B8

36 to 39

Pn8A2

Pn8BA

40 to 43

Pn8A4

Pn8BC

44 to 47

Pn8A6

Pn8BE

Example: Pn8A8 = 87 65 43 21