Figure 3.7.30 register for port g – Toshiba H1 Series User Manual

Page 147

Advertising
background image

TMP92CZ26A

92CZ26A-144

Port G register

7 6 5 4 3 2 1 0

Bit

Symbol

PG5 PG4 PG3 PG2 PG1 PG0

Read/Write

R

After reset

Data from external port

Note: Selection of the input channel of AD converter and ADTRG input mode register is enabled by setting AD converter.

Port G Function register

7 6 5 4 3 2 1 0

Bit

Symbol

PG3F

Read/Write

W

After

reset

0

Function

0: Input port

or AN3

1:

ADTRG

Port G driver register

7 6 5 4 3 2 1 0

Bit Symbol

PG3D

PG2D

Read/Write

R/W

After reset

1

1

Function

Input/Output

buffer

drive register for

standby mode

Figure 3.7.30 Register for Port G

Note 1: Read-Modify-Write is prohibited for the registers PGFC.

Note 2: (PG) register is prohibited to access by byte. All the instruction (Arithmetic/ Logical/ Bit operation and rotate/ shift

instruction) access by byte are prohibited. Word access is always needed.

Example:

LD

wa, (PG)

: Using only “a” register data, and cancel “w” register data.

Note 3: Don’t use PG register at the state that mingles Analog input and Digital input.

PG
(0040H)

PGDR
(0090H)

PGFC
(0043H)

Advertising