Toshiba H1 Series User Manual

Page 543

Advertising
background image

TMP92CZ26A

92CZ26A-540

LCD Control 0 Register

7 6 5 4 3 2 1 0

bit Symbol

PIPE

ALL0

FRMON

DLS

LCP0OC

START

Read/Write R/W

R/W

R/W R/W

R/W

R/W R/W

After reset

0

0

0

0

0

0

0

Function

PIP

function

0:Disable

1:Enable

Segment

data

setting

0: Normal

1: Always

output “0”

Frame

divide

setting

0: Disable

1: Enable

Always

write “0”

LFR

signal

LCP0/line

selection

0:Line

1:LCP0

LCP0 (Note)

0: Always

output

1: At valid

data only

LLOAD

width

0: At setting

in register

1: At valid

data only

LCDC

operation

0: Stop

1: Start

Note: When select STN mode, LCP0 is output at valid data only regardless of the setting of <LCP0OC> bit.

Divide FRM 0 Register

7 6 5 4 3 2 1 0

bit Symbol

FMP3

FMP2

FMP1

FMP0

FML3

FML2

FML1

FML0

Read/Write R/W

After

reset

0 0 0 0 0 0 0 0

Function

LCP0 DVM (bits 3-0) (M)

LHSYNC DVM (bits 3-0) (N)

7 6 5 4 3 2 1 0

bit Symbol

FMP7

FMP6

FMP5

FMP4

FML7

FML6

FML5

FML4

Read/Write R/W

After

reset

0 0 0 0 0 0 0 0

Function

LCP0 DVM (bits7-4) (M)

LHSYNC DVM (bits 7-4) (N)

LCDDVM0

(0283H)

LCDDVM1

(0284H)