Page rom read cycle, Tmp92cz26a, Ac measuring condition – Toshiba H1 Series User Manual

Page 653

Advertising
background image

TMP92CZ26A

92CZ26A-650

4.3.2

Page ROM Read Cycle

(1) 3-2-2-2 mode

Variable

Parameter Symbol

Min Max

80 MHz 60 MHz Unit

1 System clock period ( = T)

t

CYC

12.5 266.6

12.5

16.6

2 A0,

A1

→ D0 ~ D15 input

t

AD2

2.0T

− 18

7

15.2

3 A2 ~ A23

→ D0 ~ D15 input

t

AD3

3.0T

− 18

19.5

31.8

4

RD

falling

→ D0 ~ D15 input

t

RD3

2.5T

− 18 13 24

5 A0 ~ A23 Invalid → D0 ~ D15 hold

t

HA

0

0 0

6

RD

rising

→ D0 ~ D15 hold

t

HR

0

0 0

ns

AC measuring condition

Note: The (a), (b) and (c) of “Symbol” in above table depend on the falling timing of

RD

pin. The falling timing of

RD

pin is set by MEMCR0<RDTMG1:0> in memory controller. If MEMCR0<RDTMG1:0> is set to “00”, it

correspond with (a) in above table, and “01” is (b), “10” is (c).



















SDCLK

A2~A23

A0~A1

2

CS

RD

D0~D15

+0

+1

+2

+3

Data
input

Data
input

Data
input

Data
input

t

AD3

t

AD2

t

AD2

t

AD2

t

HA

t

HR

t

RD3

t

HA

t

HA

t

HA

t

CYC

Advertising