3 ac characteristics, 1 basic bus cycle, Tmp92cz26a – Toshiba H1 Series User Manual

Page 648: Output level: high = 0.7 3av, Low = 0.3 3av, Input level: high = 0.9 3av, Low = 0.1 3av

Advertising
background image

TMP92CZ26A

92CZ26A-645

4.3 AC

Characteristics

The Following all AC regulation is the measurement result in following condition, if unless otherwise noted.

AC measuring condition

Clock of top column in above table shows system clock frequency, and “T” shows system

clock period [ns].

Output level: High

= 0.7 3AV

CC

, Low

= 0.3 3AV

CC

Input level: High

= 0.9 3AV

CC

, Low

= 0.1 3AV

CC

Note: In table, “Variable” shows the regulation at DVCC3A=3.0V~3.6V, DVCC1A=DVCC1B=DVCC1C=1.4~1.6V.

4.3.1

Basic Bus Cycle

Read cycle

Variable

No. Parameter Symbol

Min Max

80 MHz 60 MHz Unit

1 OSC period (X1/X2)

t

OSC

100 166.6

2 System clock period (

= T)

t

CYC

12.5 266.6 12.5 16.6

3 SDCLK

low

width

t

CL

0.5T

− 3

3.25

5.3

4 SDCLK

high

width

t

CH

0.5T

− 3

3.25

5.3

5-1

A0 ~ A23 valid

→ D0 ~ D15 input at 0

waits

t

AD

2.0T

− 18.0

7

15.3

t

AD6

6.0T

− 18.0

82

5-2

A0 ~ A23 valid

→ D0 ~ D15 input at

4 waits

/6 waits

t

AD7

8.0T - 18.0

82

t

RD

1.5T

− 18.0

7

6-1

RD

falling

→ D0 ~ D15 input at 0 waits

t

RD

1.5T

− 18.0

0.75

t

RD6

5.5T

− 18.0

73.6

6-2

RD

falling

→ D0 ~ D15 input at

4 waits

/6waits

t

RD7

5.5T

− 18.0

50.75

7-1

RD

low width at 0 waits

t

RR

1.5T

− 10

8.75

14.9

7-2

RD

low width at

4 waits

t

RR6

5.5T

− 10

58.75

81.3

8 A0 ~ A23 valid →

RD

falling

t

AR

0.5T

− 5

1.25

3.3

9

RD

falling

→ SDCLK rising

t

RK

0.5T

− 5

1.25

3.3

10 A0 ~ A23 valid

→ D0 ~ D15 hold

t

HA

0 0

0

11

RD

rising

→ D0 ~ D15 hold

t

HR

0 0

0

12

WAIT

setup time

t

TK

3 3

5

13

WAIT

hold time

t

KT

2

2 3

14 Data byte control access time

t

SBA

1.5T

− 18.0

0.75

7

15

RD

high width

t

RRH

0.5T

− 5

1.25

3.3

ns

AC measuring condition

• Data_bus, Address_bus, various function control signal capacitance C

L

= 50 pF

Note: The operation guarantee temprature: 80MHz: Ta=0

∼50°C

,

less than 60MHz: Ta=0

∼70°C

Advertising
This manual is related to the following products: