3.16.10 Supplement

(1) External access flow to USB communication

a) Normally movement

b) Stage error

SETUP DATA0 ACK

IN

NAK

DATA1

DATA0

DATA1

INT_SETUP

INT_ ENDPOINT0

INT_STATUS

REQUEST FLAG

EP0 FIFO access

Request access

Setup Received access

IN

ACK

IN

ACK

OUT

ACK

EOP register access

Stage error

SETUP DATA0 ACK

IN

NAK

DATA1

DATA0

DATA0

INT_SETUP

INT_ ENDPOINT0

INT_STATUS

REQUEST FLAG

EP0 FIFO access

Request access

Setup Received access

IN

ACK

IN

ACK

ACK

EOP register access

SETUP

Stage error bit

STATUS register read

Normal