TMP92CZ26A

92CZ26A-644


Symbol Parameter

Min

Typ.

Max

Unit

Condition

15 30

DVCC3A,3B = 3.6V

NORMAL (note2)

45 60

DVCC1A,1B,1C = 1.6V

0.5 1

DVCC3A,3B = 3.6V

IDLE2

28 45

PLL_ON

f

SYS

=80MHz

DVCC1A,1B,1C = 1.6V

12 23

DVCC3A,3B = 3.6V

NORMAL (note2)

34 45

DVCC1A,1B,1C = 1.6V

0.4 0.8

DVCC3A,3B = 3.6V

IDLE2

21 34

mA

PLL_ON

f

SYS

=60MHz

DVCC1A,1B,1C = 1.6V

12 45

DVCC3A,3B = 3.6V

IDLE1

200

3200

μA

PLL_OFF

f

SYS

=10MHz

DVCC1A,1B,1C = 1.6V

35

Ta

70

6

30

Ta

50

DVCC3A=3.6V
DVCC3B=3.6V

AVCC=3.6V

50

Ta

70

Power Cut Mode
(WITH PMC function )

2

35

Ta

50

DVCC1A=0V

DVCC1B=1.6V

DVCC1C=0V

XT=32KHz

X=OFF

35

Ta

70

6

30

Ta

50

DVCC3A=3.6V
DVCC3B=3.6V

AVCC3.6V

800

Ta

70

ICC

STOP

200

600

μA

Ta

50

DVCC1A=1.6V
DVCC1B=1.6V
DVCC1C=1.6V

XT=OFF

X=OFF

Note1 : Typical values are value that when Ta

= 25°C and Vcc = 3.3 V unless otherwise noted.