92CZ26A-583

3.21.5 Operational

description

(1) Reading timer data

There is the case, which reads wrong data when carry of the inside counter happens

during the operation which clock data reads. Therefore please read two times with the
following way for reading correct data.

Figure 3.21.2 Flowchart of timer data read

Start

END

PAGER<PAGE>

= “0” ,

Select PAGE0

Read the clock data

(1st)

Read the clock data

(2nd)

1st data

= 2nd data

NO

YES