TMP92CZ26A

92CZ26A-63

Table 3.4.19 Information Returned for the Microcontroller Information Command

Microcontroller Information

ASCII Code

TMP92CZ26A

54H, 4DH, 50H, 39H, 32H, 43H, 5AH, 32H, 36H,20H, 20H, 20H, 20H, 20H, 20H

Table 3.4.20 Information Returned for the User Program Transfer Result Command

Transfer Result

Value

Error Conditions

No error

00H

User program not received

02H

The user program transfer result is received without the user program

transfer start command being received first.

Received file not in Intel Hex format

04H

The first data of a user program is not “:” (3AH).

User program size error

06H

The size of a received user program is larger than the value set in
wIndex of the user program transfer start command.

Download address error

08H

The specified user program download address is not in the designated

area.

The user program size is over 10 Kbytes.

Protocol error or other error

0AH

The user program transfer start or user program transfer result
command is received first.

A checksum error is detected in the Intel Hex file.

A record type error is detected in the Intel Hex file.

The length of an address record in the Intel Hex file is 3 or longer.

The length of an end record in the Intel Hex file is other than 0.