3 basic functions and register setting – Toshiba H1 Series User Manual

Page 188

Advertising
background image

TMP92CZ26A

92CZ26A-185

3.8.3 Basic functions and register setting

In this section, setting of the block address area, the connecting memory and the number

of waits out of the memory controller’s functions are described.

(1) Block address area specification

The block address areas of CS0 to CS3 are specified by MSAR0 to MSAR3 and MAMR0 to

MAMR3.

(a) Memory start address register

Figure 3.8.1 shows the memory start address registers. MSAR0 to MSAR3 set the start

addresses for the CS0 to CS3 areas. Set the upper eight bits (A23 to A16) of the start
address in <S23:16>. The lower 16 bits of the start address (A15 to A0) are permanently set
to 0. Accordingly, the start address can only be set in 64-Kbyte increments, starting from
000000H. Figure 3.8.2 shows the relationship between the start address and the start
address register value.

Memory Start Address Registers (for areas CS0 to CS3)

7 6 5 4 3 2 1 0

Bit

symbol

S23 S22 S21 S20 S19 S18 S17 S16

Read/Write

R/W

After

reset

1 1 1 1 1 1 1 1

Function

Determines A23 to A16 of start address

Figure 3.8.1 Memory Start Address Register

64KByte

Address

000000H

FFFFFFH

000000H .................... 00H

010000H .................... 01H

020000H .................... 02H

030000H .................... 03H

040000H .................... 04H

050000H .................... 05H

060000H .................... 06H

FF0000H ................... FFH

Start Address

Value in start address register (MSAR0 to MSAR3)

to

to

Figure 3.8.2 Relationship between Start Address and Start Address Register Value

MSAR0
(0143H)

MSAR1
(0147H)

MSAR2
(014BH)

MSAR3
(014FH)

Sets start addresses for areas CS0 to CS3

Advertising