Toshiba H1 Series User Manual

Page 484

Advertising
background image

TMP92CZ26A

92CZ26A-481

(h) <SWRST>

This bit is for Software reset of transmit/receive FIFO pointer. Write SPICT<TXE> to

“0” at <XEN>="1", and stop transmitting. After that, by writing <SWRST> to “1”, the
read/write pointer of transmit/receive FIFO are initialized.

When writing SPICT<TXE> to “0”, stops transmission after the UNIT data in

transmitting is transmitted. Write <SWRST> to“1”, the data in the transmit FIFO
becomes to invalid.

The data in the transmit shift register is cleared simultaneously. Therefore, the data is

not output if transmit is restarted after executed software reset.

Please do not write <SWRST> to “1” during transmission. In case of receiving, the

received data in the receive FIFO buffer becomes invalid. However, the UNIT data in
receiving is loaded to receive FIFO as valid data.

In case of sequential receive, receiving operates sequentially even if the data of receive

buffer becomes invalid. Therefore, stops receive operation by writing
SPICT<RXE>=“0”after finishing to receive all the data in receiving. And all the receive
operation is stopped by writing <SWRST>=“1”after checking no UNIT data in receiving
(namely after REND interrupt or the time to receive 1UNIT).

During receiving, do not write <SWRST>=“1”.
Software reset can be executed by 1 shot operation; writing <SWRST>=“1” (needless to

write <SWRST>=“0”). Writing <XEN>=“1”and <SWRST>=“1”simultaneously is permitted.


(i) <XEN>

Enable/disable control of root clock this SPI controller.


(j)

<CLKSEL2:0>

Select baud rate. Baud rate is created from f

SYS

and settings are in under table.

Please change the setting when transmitting/receiving are not in operation.

Note: When setting the baud rates, select less than 20Mbps according to the operation speed of CPU (f

SYS

).

Table 3.17.1 Example of Baud Rate

Baud Rate [Mbps]

<CLKSEL2:0>

f

SYS

=60MHz

f

SYS

=80MHz

f

SYS

/2

f

SYS

/3

20

f

SYS

/4

15 20

f

SYS

/8

7.5 10

f

SYS

/16

3.75 5

f

SYS

/64

0.9375 1.25

f

SYS

/256

0.234375 0.3125

Advertising