TMP92CZ26A

92CZ26A-398

3.16.3.17 EOP Register

This register is used when a dataphase of control transfer type terminate or when a

short packet is transmitting of bulk-IN, interrupt-IN.

7 6 5 4 3 2 1 0

bit Symbol

EP7_EOPB EP6_EOPB EP5_EOPB

EP4_EOPB

EP3_EOPB

EP2_EOPB EP1_EOPB EP0_EOPB

Read/Write

W W W W W W W W

After

reset

1 1 1 1 1 1 1 1

Note: EOP<EP7_EOPB, EP6_EOPB, EP5_EOPB, EP4_EOPB> registers are not used at TMP92CZ26A.

In a dataphase of control transfer type, write “0” to <EP0_EOPB> when all

transmission data is written to the FIFO, or read all receiving data from the FIFO.
UDC is terminated status stage by this signal.

When short packet is transmitted by using bulk-IN or interrupt-IN endpoint, use

this for terminate writing transmission data. In this case, write “0” to <EP0_EOPB> of
writing endpoint. Write “1” to another bit.

EOP

(07CFH)