92CZ26A-567





















Figure 3.20.4 Timing diagram of de-bounce circuit

INT4

Reset the counter for de-bounce time

P96/INT4 pin

Start the counter for de-bounce time

de-bounce time

de-bounce time

INT4 is generated by matching counter and
specified de-bounce time.

After pen is de-touched, INT4 can be issued
again.

de-bounce time

INT4 isn’t generated by matching counter and specified
de-bounce time because of it is an edge-type interrupt.