Toshiba H1 Series User Manual

Page 395

Advertising
background image

TMP92CZ26A

92CZ26A-392


FIFO_DISABLE (Bit1)

0: FIFO enabled

1: FIFO disabled

This bit symbol shows FIFO status except EP0.
If the FIFO is set to disabled, the UDC transmits NAK

handshake forcibly for the all transfer. Disabled or enabled is set
by COMMAND register. This bit is cleared to “0” when transfer
type is changed.

STAGE_ERROR (Bit0)

0:

SUCCESS

1:

ERROR

This bit symbol shows that status stage is not terminated

correctly. ERROR is set when a status stage is not terminated
correctly and new SETUP token is received.

When this bit is “1”, this bit is cleared to “0” by read

EP0_STATUS register. This bit is not cleared even if normal

control transfer or other transfer is executed after. To clear, read

this bit. When software transaction is finished and UDC writes

EOP register, UDC shifts to status register and waits

termination of status stage. In this case, if software is needed to

confirm that status stage is terminated correctly, when a new

request flag is received, it can be confirmed that whether last

request terminate correctly or not. And during request routine in

software, when new request flag is asserted, it can be confirmed

that whether last request is canceled or not halfway.

Advertising
This manual is related to the following products: