TMP92CZ26A

92CZ26A-593

3.22.3.2 Alarm

generator

The Alarm function generates eight kinds of alarm waveform having a modulation

frequency 4096Hz determined by the low-speed clock (32.768 KHz). And this waveform is
reversible by setting a value to a register.

By connecting a loud speaker outside, Alarm tone can easily sound.
Five kind of fixed cycles (1Hz, 2Hz, 64Hz, 512Hz, 8192Hz) interrupt be generate by using

a counter which is used for alarm generator.


(Operation)
At first, MELALMC<MELALM> have to be set as “0” in order to select alarm waveform

as output waveform from MLDALM. Then “10” be set on MELALMC<FC1:0> register, and
clear internal counter. Finally alarm pattern has to be set on 8-bit register of ALM. If it is
inverted output-data, set <ALMINV> as invert.

Followings are example program, setting value of alarm pattern and waveform of each

setting value.



(Setting value of alarm pattern)

Setting value

for ALM

register

Alarm waveform

00H “0”

fixed

01H AL1

pattern

02H AL2

pattern

04H AL3

pattern

08H AL4

pattern

10H AL5

pattern

20H AL6pattern

40H AL7

pattern

80H AL8

pattern

Other Undefined

(Do not set)


(Example program)

In case of outputting AL2 pattern (31.25ms/8 times/1sec)

LD

(MELALMC), C0H

;

Set output alarm waveform

;

Free-run counter start

LD

(ALM), 02H

;

Set AL2 pattern, start