6 timer input pulse (ta0in, ta2in, tb0in0, tb1in0), 7 interrupt operation, 8 usb timing (full-speed) – Toshiba H1 Series User Manual

Page 663: Tmp92cz26a

Advertising
background image

TMP92CZ26A

92CZ26A-660

4.3.6

Timer input pulse (TA0IN, TA2IN, TB0IN0, TB1IN0)

Variable

Parameter Symbol

Min Max

80 MHz 60 MHz Unit

Clock cycle

t

VCK

8T+100

200

234

Low level pulse width

t

VCKL

4T

+ 40

90

107

High level pulse width

t

VCKH

4T

+ 40

90

107

ns

4.3.7 Interrupt

Operation

Variable

Parameter Symbol

Min Max

80 MHz 60 MHz Unit

INT0~INT7 low width

t

INTAL

2T

+ 40

65

74

INT0~INT7 high width

t

INTAH

2T

+ 40

65

74

ns

4.3.8 USB

Timing

(Full-speed)

V

CC

= 3.3 ± 0.3 V/f

USB

= 48 MHz/Ta = 0 ~ 70°C

Parameter Symbol

Min

Max

Unit

D

+, D− rising time

t

R

4 20

D

+, D− falling time

t

F

4 20

ns

Output signal crossover voltage

V

CRS

1.3 2.0

V

AC measuring condition













D

+

D

TMP92CZ26A

R1 = 27

Ω

R1 = 27

Ω

R2 = 15 k

Ω

CL = 50 pF

R3 = 1.5 k

Ω

V

CC

Measuring

positoin

D

+, D−

V

CRS

90%

90%

10%

10%

t

R

t

F