Toshiba H1 Series User Manual

Page 322

Advertising
background image

TMP92CZ26A

92CZ26A-319

• Integer divider (N divider)

For example, when the source clock frequency (f

c

) is 19.6608 MHz, the input

clock is

φT2, the frequency divider N (BR0CR<BR0S3:0>) = 8, and

BR0CR<BR0ADDE> = 0, the baud rate in UART Mode is as follows:


*Clock state System clock

:

1/1

Prescaler clock

:

1/2


Baud Rate

= = 19.6608106 Ч 10

6

ч 16 ч 8 ч 16 = 9600 (bps)

Note: The N + (16 – K) / 16 division function is disabled and setting BR0ADD

<BR0K3:0> is invalid.

• N+(16-K)/16 divider (UART Mode only)

Accordingly, when the source clock frequency (fc) = 15.9744 MHz, the input

clock is

φT2, the frequency divider N (BR0CR<BR0S3:0>) = 6, K

(BR0ADD<BR0K3:0>) = 8, and BR0CR <BR0ADDE> = 1, the baud rate in UART
Mode is as follows:


*Clock state System clock

:

1/1

Prescaler clock

:

1/2

Baud Rate

= ч 16 = 15.9744 Ч 10

6

ч 16ч (6 + ) ч 16

= 9600 (bps)

Table 3.14.2 show examples of UART Mode transfer rates.

Additionally, the external clock input is available in the serial clock. (Serial

Channel 0). The method for calculating the baud rate is explained below:

• In UART Mode

Baud rate = external clock input frequency

÷ 16

It is necessary to satisfy (external clock input cycle)

≥ 4/f

SYS

• In I/O Interface Mode

Baud rate = external clock input frequency
It is necessary to satisfy (external clock input cycle)

≥ 16/f

SYS

÷ 16

f

C

/16
8

f

C

/16

6 + (16 – 8)

16

8

16

Advertising