Toshiba H1 Series User Manual

Page 20

Advertising
background image

TMP92CZ26A

92CZ26A-17

This LSI has the restriction for the order of supplying power. Be sure to supply external
3.3V power with 1.5V power is supplied.




















Note1: Inernal 1.5 V and External 3.3V power supply can be set to ON/OFF at the same time. However, external pin

may become unstable condition momentary. Therefore, set external power supply to

ON/OFF during internal

power supply is stabile like above figure if there is possibility to affect machinery connected with micro controller.

Note2: When setting to ON, don’t set 3.3V power supply earlier than 1.5V power supply. When setting to OFF, don’t

set to 3.3V power supply later than 1.5 V power supply.

Figure 3.1.2 Power on Reset Timing Example

DVCC1A

DVCC1B

DVCC1C

RESET

AVCC

DVCC3B

DVCC3A

Power supply is rising with

in 100mS, and stabilizes.

After 1.5V power

supply is falling, set

3.3V to OFF.

After 1.5V power

supply is rising,

set 3.3V to ON.

Power supply is falling with

in 100mS, and stabilizes.

High-frequency oscillation

stabilization time

20 system clock

1.5V

Power

3.3V

Power

Stand-by Mode (PMC)

Power On

Power Off

PWE terminal