TMP92CZ26A

92CZ26A-535

4. LGOE0 to LGOE2 Signals

The LCDC has three signals (LGOE0 to LGOE2) that can be controlled like the

LHSYNC signal. For these signals, the enable width, delay time, and phase timing can

be adjusted as shown below.

7 6 5 4 3 2 1 0

bit

Symbol O0W7 O0W6 O0W5 O0W4 O0W3 O0W2 O0W1 O0W0

Read/Write W

After

reset

0 0 0 0 0 0 0 0

Function

LGOE0 width (bits 7-0)

7 6 5 4 3 2 1 0

bit

Symbol O1W7 O1W6 O1W5 O1W4 O1W3 O1W2 O1W1 O1W0

Read/Write W

After

reset

0 0 0 0 0 0 0 0

Function

LGOE1 width (bits 7-0)

7 6 5 4 3 2 1 0

bit

Symbol O2W7 O2W6 O2W5 O2W4 O2W3 O2W2 O2W1 O2W0

Read/Write W

After

reset

0 0 0 0 0 0 0 0

Function

LGOE2 width (bits 7-0)

7 6 5 4 3 2 1 0

bit

Symbol O2W9 O2W8 O1W9 O1W8 O0W8 LDW9 LDW8 HSW8

Read/Write W

After

reset

0 0 0 0 0 0 0 0

Function

LGOE2 width (bits 9-8) LGOE1 width (bits 9-8)

LGOE0

width

(bit 8)

LLOAD width (bits 9-8)

LHSYNC

width

(bit 8)

LCP0

Signal Name

LGOE0 signal

LGOE1 signal

LGOE2 signal

High width setting

LGOE0: LCP0 clock = 1, 2, 3 … 512 pulses

LGOE1: LCP0 clock = 1, 2, 3 … 1024 pulses

LGOE2: LCP0 clock = 1, 2, 3 … 1024 pulses

LCDHO0W

(0296H)

LCDHO1W

(0297H)

LCDHO2W

(0298H)

LCDHWB8