4 nand flash controller ac characteristics, Tmp92cz26a, Ac measuring condition – Toshiba H1 Series User Manual

Page 661

Advertising
background image

TMP92CZ26A

92CZ26A-658

4.3.4

NAND Flash Controller AC Characteristics

Variable

No. Symbol

Parameter

Min Max

80 MHz

(n=3)

(m=3)

60 MHz

(n=3)

(m=3)

Unit

1

t

NC

Access cycle

(2 + n + m ) T

100

132

2

t

RP

NDRE

low level width

(1.5

+ n) T − 12

45

63

3

t

REA

NDRE

data access time

(1.5

+ n) T − 15

41

60

4

t

OH

Read data hold time

0

0

0

5

t

WP

NDWE

low level width

(1.0

+ n) T − 20

30

47

6

t

DS

Write data setup time

(1.0

+ n) T − 20

30

47

7

t

DH

Write data hold time

(0.5 + m) T

− 2

42

56

ns

AC measuring condition

Note1: The “n” in “Variable” means wait-number which is set to NDFMCR0<SPLW1:0>, and “m” means number which is

set to NDFMCR0<SPHW1:0>.

Example: If NDFMCR0<SPLW1:0> is set to “01”, n=1, t

RP

= (1.5 + n) T − 12 = 2.5T − 12

Note2: In above variable, the setting that result is minus can not use.

























Data input

SDCLK

A0~A23

NDRE

NDWE

D0~D7
D0~D15

t

RP

t

REA

t

OH

Read
cycle

Data output

NDRE

NDWE

D0~D7
D0~D15

t

WP

t

DH

Write
cycle

t

DS

SPLW1:0="01"

SPHW1:0="01"

t

CYC

Advertising
This manual is related to the following products: