20) rtc (real-time clock) symbol name – Toshiba H1 Series User Manual

Page 745

Advertising
background image

TMP92CZ26A

92CZ26A-742

(20) RTC (Real-Time Clock)

Symbol Name

Address

7 6 5 4 3 2 1 0

SE6 SE5 SE4 SE3 SE2 SE1 SE0

R/W
Undefined

SECR

Second
register

1320H

“0” is read

40 sec.

20 sec.

10 sec.

8 sec.

4 sec.

2 sec.

1 sec.

MI6 MI5 MI4 MI3 MI2 MI1 MI0
R/W
Undefined

MINR

Minute

register

1321H

“0” is read

40 min.

20 min.

10 min.

8 min.

4 min.

2 min.

1 min.

HO5 HO4 HO3 HO2 HO1 HO0

R/W

Undefined

HOURR

Hour

register

1322H

“0” is read

20 hours
(PM/AM)

10 hours

8 hours

4 hours

2 hours

1 hour

WE2

WE1

WE0

R/W

Undefined

DAYR

Day

register

1323H

“0” is read

W2

W1

W0

DA5 DA4 DA3 DA2 DA1 DA0

R/W

Undefined

DATER

Date

register

1324H

“0” is read

20 days

10 days

8 days

4 days

2 days

1 day

MO4

MO3

MO2

MO1

MO0

R/W

1325H

Undefined

PAGE0

“0” is read

10 month

8 month

4 month

2 month

1 month

MONTHR

Month

register

PAGE1

“0” is read

0: Indicator

for 12

hours
1: Indicator

for 24

hours

YE7 YE6 YE5 YE4 YE3 YE2 YE1 YE0

R/W

1326H

Undefined

PAGE0

80 years

40 years

20 years

10 years

8 years

4 years

2 years

1 year

YEARR

Year

register

PAGE1

“0” is read

Leap year setting
00: Leap year
01: One year after
10: Two years after
11: Three years after

INTENA

ADJUST

ENATMR

ENAALM PAGE

R/W

W

R/W

R/W

0

Undefined

Undefined

Undefined

PAGER

Page

register

1327H

(Prohibit

RMW)

Interrupt

1: Enable

0: Disable

“0” is read

1: Adjust

TIMER

1: Enable

0: Disable

ALARM

1: Enable

0: Disable

“0” is
read.

PAGE

selection

DIS1HZ

DIS16HZ

RSTTMR

RSTALM

RE3 RE2 RE1 RE0

W

Undefined

RESTR

Reset

register

1328H

(Prohibit

RMW)

0: 1 Hz

0: 16 Hz

1:Clock

reset

1: Alarm

reset

Always write “0”

Advertising