Toshiba H1 Series User Manual

Page 346

Advertising
background image

TMP92CZ26A

92CZ26A-343

7 6 5 4 3 2 1 0

Bit symbol

PLSEL

RXSEL

TXEN

RXEN

SIRWD3

SIRWD2

SIRWD1

SIRWD0

Read/Write R/W

After

reset

0 0 0 0 0 0 0 0

Function

Select
transmit
pulse width
0: 3/16
1: 1/16

Receive

data

0: “H” pulse

1: “L” pulse

Transmit
0: disable
1: enable

Receive
0: disable

1: enable

Select receive pulse width
Set effective pulse width for equal or more than 2x

×

(value

+ 1) + 100ns

Can be set : 1 to 14
Can not be set : 0, 15

Select receive pulse width
Formula: Effective pulse width

≥ 2x × (value + 1) + 100ns

x

=

1/f

FPH

0000 Cannot

be

set

0001

Equal or more than 4x + 100ns

to

1110

Equal or more than 30x + 100ns

1111

Can not be set

Receive (recovery) operation

0

Disable receiving operation

(Received data is ignored)

1 Enabled

receiving

operation

Transmit (modulation) operation

0 Disabled

transmission

operation

(Input from SIO is ignored)

1 Enabled

transmission

operation

Select transmit pulse width

0 3/16

pulse

width

1 1/16

pulse

width

SIRCR

(1207H)

Figure 3.14.21 IrDA Control Register