Toshiba H1 Series User Manual

Page 42

Advertising
background image

TMP92CZ26A

92CZ26A-39

c. STOP Mode

When STOP Mode is selected, all internal circuits stop, including the internal

oscillator.

After STOP Mode has been cleared system clock output starts when the warm-up

time has elapsed, in order to allow oscillation to stabilize.

Figure 3.3.10 illustrates the timing for clearance of the STOP Mode Halt state by an

interrupt.












Figure 3.3.10 Timing chart for STOP Mode Halt state cleared by interrupt


Table 3.3.5 Example of warming-up time after releasing STOP-mode

@f

OSCH

=10 MHz

SYSCR2<WUPTM1:0>

01 (2

8

) 10

(2

14

) 11

(2

16

)

25.6 us

1.6384 ms

6.5536 ms

Interrupt for

releasing Halt

Data

Data

STOP

mode

Warm-up

time

X1

A0~A23

D0~D31

RD