Toshiba H1 Series User Manual

Page 33

Advertising
background image

TMP92CZ26A

92CZ26A-30

Limitation point on the use of PLL0

1. If you stop PLL operation during using PLL0, you should execute following setting in

the same order.

LD

(PLLCR0),X0XXXXXXB

;

Change the clock f

PLL

to f

OSCH

LD

(PLLCR1),0XXXXXXXB

;

Stop

PLL0

X: Don't care

2. If you shift to STOP mode during using PLL, you should execute following setting in the

same order.

LD

(SYSCR2),

XXXX01XXB ;

Set the STOP mode

LD

(PLLCR0),

X0XXXXXXB

;

Change the system clock f

PLL

to f

OSCH

LD

(PLLCR1),

0XXXXXXXB

;

Stop

PLL0

HALT

;

Shift to STOP mode

X: Don't care

Examples of settings are below;

(1) Start Up / Change Control

(OK) High frequency oscillator operation mode(f

OSCH

) PLL0 start up

PLL0 use mode (f

PLL

)

LD

(PLLCR1), 1XXXXXXXB

;

PLL0 start up / lock up start

LUP: BIT

5,(PLLCR0)

;

JR

Z,LUP

;

Check for the flag of lock up end

LD

(PLLCR0), X1XXXXXXB

;

Change the system clock fOSCH to fPLL

X: Don't care

(2) Change / Stop Control

(OK)

PLL0 use mode (f

PLL

) High frequency oscillator operation mode(f

OSCH

)

PLL0 Stop

LD

(PLLCR0),X0XXXXXXB

;

Change the system clock fPLL to fOSCH

LD

(PLLCR1),0XXXXXXXB

;

Stop PLL0

X: Don't care

(OK) PLL0 use mode (f

PLL

) Set the STOP mode

High frequency oscillator operation mode (f

OSCH

) PLL stop

HALT(High frequency oscillator stop)

LD

(SYSCR2),XXXX01XXB

;

Set the STOP mode

(This command can be executed before use of PLL0)

LD

(PLLCR0),X0XXXXXXB

;

Change the system clock f

PLL

to f

OSCH

LD

(PLLCR1),0XXXXXXXB

;

Stop PLL0

HALT

;

Shift to STOP mode

X: Don't care

(NG) PLL0 use mode (f

PLL

) Set the STOP mode

HALT(High frequency oscillator stop)

LD

(SYSCR2),XXXX01XXB

;

Set the STOP mode

(This command can be executed before use of PLL0)

HALT

;

Shift to STOP mode

X: Don't care