92CZ26A-578

(3) Hour column register (for PAGE0/1)

1.

In case of 24-hour clock mode (MONTHR<MO0>= “1”)

7 6 5 4 3 2 1 0

Bit symbol

HO5

HO4 HO3 HO2 HO1 HO0

HOURR
(1322H)

Read/Write

R/W

After

reset

Undefined

Function

"0" is read.

20 hour

column

10 hour

column

8 hour

column

4 hour

column

2 hour

column

1 hour

column

0 0 0 0 0 0

0

o’clock

0 0 0 0 0 1

1

o’clock

0 0 0 0 1 0

2

o’clock

:

0 0 1 0 0 0

8

o’clock

0 0 1 0 0 1

9

o’clock

0 1 0 0 0 0

10

o’clock

:

0 1 1 0 0 1

19

o’clock

1 0 0 0 0 0

20

o’clock

:

1 0 0 0 1 1 23

Note: Do not set the data other than showing above.

2.

In case of 24-hour clock mode (MONTHR<MO0>= “0”)

7 6 5 4 3 2 1 0

Bit symbol

HO5

HO4 HO3 HO2 HO1 HO0

HOURR
(1322H)

Read/Write

R/W

After

reset

Undefined

Function

"0" is read.

PM/AM

10 hour

column

8 hour

column

4 hour

column

2 hour

column

1 hour

column

0 0 0 0 0 0

0 o’clock

(AM)

0 0 0 0 0 1

1

o’clock

0 0 0 0 1 0

2

o’clock

:

0 0 1 0 0 1

9

o’clock

0 1 0 0 0 0

10

o’clock

0 1 0 0 0 1

11

o’clock

1 0 0 0 0 0

0

o’clock

(PM)

1 0 0 0 0 1

1

o’clock

Note: Do not set the data other than showing above.