Figure 3.23.8 ad conversion registers – Toshiba H1 Series User Manual

Page 605

Advertising
background image

TMP92CZ26A

92CZ26A-602

AD Conversion Result Register 4 Low

7 6 5 4 3 2 1 0

bit

Symbol

ADR41

ADR40

OVR4

ADR4RF

Read/Write R

R

R

After

reset

0

0

0

0

Function

Store Lower 2 bits of

AN4 AD conversion

result

Overrun

flag


0:No generate
1: Generate

AD conversion
result store
flag

1: Stored

AD Conversion Result Register 4 High

7 6 5 4 3 2 1 0

bit Symbol

ADR49

ADR48

ADR47

ADR46 ADR45 ADR44 ADR43 ADR42

Read/Write R

After

reset

0 0 0 0 0 0 0 0

Function

Store Upper 8 bits of AN4 AD conversion result

AD Conversion Result Register 5 Low

7 6 5 4 3 2 1 0

bit

Symbol

ADR51

ADR50

OVR5

ADR5RF

Read/Write R

R

R

After

reset

0

0 0

0

Function

Store Lower 2 bits of

AN5 AD conversion

result

Overrun

flag


0:No generate
1: Generate

AD conversion
result store
flag

1: Stored

AD Conversion Result Register 5 High

7 6 5 4 3 2 1 0

bit Symbol

ADR59

ADR58

ADR57

ADR56 ADR55 ADR54 ADR53 ADR52

Read/Write R

After

reset

0 0 0 0 0 0 0 0

Function

Store Upper 8 bits of AN5 AD conversion result

9

8

7

6

5

4

3

2

1

0

Channel X conversion result

7

6

5

4

3

2

1

0

7

6

5

4

3

2

1

0









Figure 3.23.8 AD Conversion Registers






ADREG4L
(12A8H)

ADREG4H
(12A9H)

ADREG5L
(12AAH)

ADREG5H
(12ABH)

ADREGxH ADREGxL

• Bits

5

∼ 2 are always read as “0”.

Bit 0 is the AD conversion result store flag <ADRxRF>. When AD conversion result is stored, the flag is set to “1”.

When Lower register (ADRECxL) is read, this bit is cleared to “0”.

Bit 1 is the Overrun flag <OVRx>. This bit is set to “1” if a next conversion result is written to the ADREGxH/L

before both the ADREGxH and ADREGxL are read. This bit is cleared to “0” by reading Flag.