Toshiba H1 Series User Manual

Page 342

Advertising
background image

TMP92CZ26A

92CZ26A-339

Setting example: To link two slave controllers serially with the master controller using the

internal clock f

IO

as the transfer clock.









• Setting the master controller













• Setting the slave controller

Main routine

P9CR

← X X X X X − 0 1

P9FC

← − − X X X − X 1

P9FC2

← X X X X X X X 1

Select P91 and P90 to function as the RXD0 and TXD0 pins

respectively (open-drain output).

INTES0

← X 1 0 0 X 1 0 0

Enable INTRX0 and INTTX0.

SC0MOD0

← 0 0 1 1 1 1 1 0

Set <WU> to 1 in 9-Bit UART Transmission Mode using f

SYS

as

the transfer clock.

Interrupt routine (INTRX0)

Acc

← SC0BUF

if Acc =Select code

Then SC0MOD0

← − − − 0 − − − − Clear <WU> to 0.

Main routine

P9CR

← X X X X X − 0 1

P9FC

← − − X X X − X 1

Set P90 and P91 to function as the TXD0 and RXD0 pins

respectively.

INTES0

← X 1 0 0 X 1 0 1

Enable the INTTX0 interrupt and set it to Interrupt Level 4.

Enable the INTRX0 interrupt and set it to Interrupt Level 5.

SC0MOD0

← 1 0 1 0 1 1 1 0

Set f

IO

as the transmission clock for 9-Bit UART Mode.

SC0BUF

← 0 0 0 0 0 0 0 1

Set the select code for slave controller 1.

Interrupt routine (INTTX0)

SC0MOD0

← 0 − − − − − − −

Set TB8 to 0.

SC0BUF

← * * * * * * * *

Set data for transmission.

TXD

RXD

Master

TXD

RXD

Slave1

TXD

RXD

Slave 2

Select code

00000001

Select code 00001010