14 serial channels (sio) – Toshiba H1 Series User Manual

Page 318

Advertising
background image

TMP92CZ26A

92CZ26A-315

3.14

Serial Channels (SIO)

TMP92CZ26A includes 1 serial I/O channel (SIO0). For both channels either UART mode

(Asynchronous transmission) or I/O interface mode (Synchronous transmission) can be selected.
And, SIO0 includes data modulator that supports the IrDA 1.0 infrared data communication
specification.






In mode 1 and mode 2, a parity bit can be added. Mode 3 has a wakeup function for making

the master controller start slave controllers via a serial link (A multi-controller system).

Figure 3.14.1 is block diagrams for each channel.
SIO0 is compounded mainly prescaler, serial clock generation circuit, receiving buffer and

control circuit, transmission buffer and control circuit.






















Figure 3.14.1 Data Formats

I/O interface mode

Mode 0: For transmitting and receiving I/O data using

the synchronizing signal SCLK for extending

UART mode

Mode 1:

7-bit data

Mode 2:

8-bit data

Mode 3:

9-bit data

Bit0

1

2

3

4

5

6

7

Bit0

1

2

3

4

5

6

Stop

Start

Bit0

1

2

3

4

5

Parity Stop

Start

6

Bit0

1

2

3

4

5

7

Stop

Start

Bit0

1

2

3

4

5

Parity Stop

Start

7

6

6

Bit0

1

2

3

4

5

8

Stop

Start

Bit0

1

2

3

4

5

Stop

Start

Bit8

6

6

7

7

Transfer direction

• Mode 0 (I/O interface mode)

• Mode 1 (7-bit UART mode)

No parity

Parity

No parity

Parity

• Mode 2 (8-bit UART mode)

• Mode 3 (9-bit UART mode)

When bit8

= 1, Address (Select code) is denoted.

When bit8

= 0, Data is denoted.

Wakeup

Advertising
This manual is related to the following products: