b. Slave Mode

z

In the Slave Mode, the start condition and the slave address are received.

After the start condition is received from the master device, while eight clocks are

output from the SCL pin, the slave address and the direction bit that are output

from the master device are received.

When a GENERAL CALL or the same address as the slave address set in I2CAR

is received, the SDA line is pulled down to the Low-level at the 9th clock, and the

acknowledge signal is output.

An INTSBI interrupt request occurs on the falling edge of the 9th clock. The

<PIN> is cleared to “0”. In Slave Mode the SCL line is pulled down to the

Low-level while the <PIN>

= “0”.

Figure 3.15.14 Start condition generation and slave address transfer

1

2

3

4

5

6

7

8

9

A6 A5 A4

A3

A2

A1

ACK

R/

W

Slave address

+ Direction bit

Acknowledge
signal from a
slave device

Start condition

SCL pin

SDA pin

<PIN>

INTSBI
interrupt request

Output of master
Output of slave

A0