Toshiba H1 Series User Manual

Page 367

Advertising
background image

TMP92CZ26A

92CZ26A-364

(4) Stop condition generation

When SBISR<BB> = “1”, the sequence for generating a stop condition start by

writing “1” to SBICR2<MST, TRX, PIN> and “0” to SBICR2<BB>. Do not modify the
contents of SBICR2<MST, TRX, PIN, BB> until a stop condition has been generated
on the bus. When the bus’s SCL line has been pulled Low by another device, the
TMP92CZ26A generates a stop condition when the other device has released the SCL
line and SDA pin rising.

7 6 5 4 3 2 1 0

SBICR2

← 1 1 0 1 1 0 0 0

Generate stop condition.

Figure 3.15.18 Stop condition generation (Single master)

Figure 3.15.19 Stop condition generation (Multi master)

SCL pin

SDA Pin

<PIN>

<BB> (Read)

Stop condition

“1”

<MST>

“1”

<TRX>

“0”

<BB>

“1”

<PIN>

Internal SCL

Internal SCL

SDA Pin

<PIN>

<BB> (Read)

Stop condition

“1”

<MST>

“1”

<TRX>

“0”

<BB>

“1”

<PIN>

SCL Pin

The case of pulled low

by another device

Advertising