Below is transmitting sequence in single packet mode.

Figure 3.16.16 Transmitting Sequence in Single Packet Mode

Transmitting number < payload

• WR of transmitting number applicable endpoint
• Total = 0

Wait transmitting

rest data

Wait transmission event

IDLE

Transmitting number > payload

• WR of payload to applicable endpoint
• Total = Total − payload

Transmission event

DATASET

= 1

DATASET register

• Check bit of EPx_DSET_A

Distinction

transmitting

EOP register

WR 0 to only bit of applicable endpoint

If transmitting number reach to

payload, applicable bit of

DATASET register is set 1

Wait transmitting

Finish

transmitting

If transmitting finish normally,

it clears applicable bit of DATASET.

Wait IN token

DATASET

= 0

• Must access to EOP register in transmitting

short packet.

• This is used showing to the closing control

transfer type.
If you access to endpoint 0, you must to
access in closing control transfer type.