92CZ26A-483

The process that calculating CRC16 of transmits data and sending CRC next to

transmit data is explained as follows.

(1) Set SPICT <CRC16_7_B> to select CRC7 or CRC16 and <CRCRX_TX_B> to select

calculating data.

(2) To reset SPICR register, write “1” after write<CRCRESET_B> to "0".
(3) Write transmit data to SPITD register, and wait for finish transmission all data.
(4) Read SPICR register, and obtain the result of CRC calculation.
(5) Transmit CRC which is obtained in (4) by the same way as (3).

CRC calculation of receive data is the same process.

Figure 3.17.7 Flow chart of CRC calculation process

Start

<CRC16_7_B>="1",

<CRCRX_TX_B>="0"

<CRCRESET_B>="0"

→"1"

Transmit all data

Read CRC from SPICR

Write CRC in SPITD and send

Finish