Toshiba H1 Series User Manual

Page 306

Advertising
background image

TMP92CZ26A

92CZ26A-303

TMRB0 Mode Register

7 6 5 4 3 2 1 0

Bit symbol

TB0CP0I

TB0CPM1

TB0CPM0

TB0CLE

TB0CLK1 TB0CLK0

Read/Write R/W W*

R/W

After

Reset

0 0 1 0 0 0 0 0

Function Always

write

“0”.

Software

capture control

0: Execute

1: Undefined

Capture timing

00:Disable

INT6 occurs at

rising edge

01:TB0IN0

INT6 occurs at

rising edge

10: TB0IN0

↑ TB0IN0 ↓

INT6 occurs at

falling edge

11: TA1OUT

TA1OUT

INT6 occurs at rising

edge

Control

Up counter

0:Disable

1: Enable

TMRB0 source clock

00: TB0IN0 input

01:

φT1

10:

φT4

11:

φT16




Figure 3.13.4 Register for TMRB (2)

TMRB0 source clock

00

TB0IN0 pin input

01

φT1

10

φT4

<TB0CLK1:0>

11

φT16

Control clearing for up counter (UC10)

0 Disable

<TB0CLE>

1

Enable clearing by match with TB0RG1

Capture/interrupt timing

Capture control

INT6 control

00 Disable

01

Capture to TB0CP0H/L at rising edge of TB0IN0

INT6 occurs at the rising

edge of TB0IN0

10

Capture to TB0CP0H/L at rising edge of TB0IN0

Capture to TB0CP1H/L at falling edge of TB0IN0

INT6 occurs at the rising

edge of TB0IN0

<TB0CPM1:0>

11

Capture to TB0CP0H/L at rising edge of TA1OUT

Capture to TB0CP1H/L at falling edge of TA1OUT

INT6 occurs at the rising

edge of TB0IN0

Software capture

0

The value of up counter is captured to TB0CP0H/L

<TB0CP0I>

1 Undefined

TB0MOD
(1182H)

Prohibit
read-
modify-
write

Advertising