TMP92CZ26A

92CZ26A-599

AD Mode Control Register 4 (AD Monitor function control)

7 6 5 4 3 2 1 0

bit

Symbol CMEN1 CMEN0 CMP1C

CMP0C

IRQEN1

IRQEN0

CMPINT1

CMPINT0

Read/Write R/W

R/W

R/W

R

R

After

reset

0 0 0 0 0 0 0 0

Function

AD Monitor

function1

0: Disable

1: Enable

AD Monitor

function0

0: Disable

1: Enable

Generation

condition of

AD monitor

function

interrupt 1

0: less than

1: Greater

than or Equal

Generation

condition of

AD monitor

function

interrupt 0

0: less than

1: Greater

than or Equal

AD monitor

function

interrupt 1

0: Disable

1: Enable

(Note)

AD monitor

function

interrupt 0

0: Disable

1: Enable

(Note)

Status of

AD monitor

function

interrupt 1

0: No

generation

1: Generation

Status of

AD monitor

function

interrupt 0

0: No

generation

1: Generation

Note: When AD monitor function interrupts generate, it is cleared automatically and it is set to

disable condition.

AD Mode Control Register 5 (AD Monitor function control)

7 6 5 4 3 2 1 0

bit Symbol

CMCH2

CM1CH1

CM1CH0

CM0CH2

CM0CH1

CM0CH0

Read/Write

R/W R/W

After

reset

0 0 0 0 0 0

Function

Select analog channel for AD monitor function 1

000: AIN0 100: AN4

001: AIN1 101: AN5

010: AIN2 110: Reserved

011: AN3 111: Reserved

Select analog channel for AD monitor function 0

000: AIN0 100: AN4

001: AIN1 101: AN5

010: AIN2 110: Reserved

011: AN3 111: Reserved



Note1: When converting AD in hard ware trigger by setting <HHTRGE> and <HTRGE>to “1”, set

PGFC<PG3F> to “1” (as ADTRG) in case of external TRG before enabling it. When using

an INTTBx0 of 16-bit timer, first set the <TSEL1:0> or <HTSEL1:0> bit to “00” when the

timer is not operating. Then, set the <HHTRGE> and <HTRGE> to “1” and enable trigger

operation. Finally, operate the timer so that AD conversion will be initiated at constant

intervals.

Note 2: When disabling an external trigger (

ADTRG

) for AD conversion, first clear the <HHTRGE> or

<HTRGE> bit to “0”, and clear the PGFC<PG3F> to “0”, thus configuring port G as a

general-purpose port.

Note 3: When starting AD by using external trigger (ADTRG), it can be started after enabling

(<HHTRGE>

= “1” or <HTRGE> = “1”) and 3 clock at f

SYS

was executed. AD is not started

when before that time.

Note 4: When chaging compare register value of AD Monitor function, change it after setting AD

Monitor function to disable(ADMOD4<CMEN1:0>=”0”).

Figure 3.23.5 AD Conversion Registers