92CZ26A-25


7 6 5 4 3 2 1 0

Bit symbol

PROTECT

EXTIN DRVOSCH

DRVOSCL

Read/Write R

R/W R/W R/W R/W

After

reset

0 0

0 1 1

Function

Protect flag

0: OFF

1: ON

Always

write “0”.

1: External

clock

fc oscillator

drive ability

1: NORMAL

0: WEAK

fs oscillator

drive ability

1: NORMAL

0: WEAK

Bit symbol

Read/Write

After reset

Function

Bit symbol

Read/Write

After reset

Function

Switching the protect ON/OFF by write to following 1

st

-KEY,2

nd

-KEY

1

st

-KEY: EMCCR1=5AH,EMCCR2=A5H in succession write

2

nd

-KEY: EMCCR1=A5H,EMCCR2=5AH in succession write

Note: In case restarting the oscillator in the stop oscillation state (e.g. Restart the oscillator in STOP mode), set

EMCCR0<DRVOSCH>, <DRVOSCL>

=”1”.