TMP92CZ26A

92CZ26A-51

(3) UART data transfer format

Table 3.4.6

to Table 3.4.11 show the supported frequencies, data transfer format, baud

rate modification command, operation command, and version management
information, respectively.

Please also refer to the description of boot program operation later in this section.

Table 3.4.6

Supported Frequencies (X1)

6.00 MHz

8.00 MHz

9.00 MHz

10.00 MHz

Note: The built-in PLL (clock multiplier) is not used regardless of the oscillation frequency.

Table 3.4.7 Transfer Format

Byte Number to

Transfer

Transfer data from PC to TMP92CZ26A

Baud Rate

Transfer data from TMP92CZ26A to PC

1st byte

2nd byte

Matching data (5AH)


− (Frequency measurement and baud
rate auto setting)

OK: Echo back data (5AH)

Error: No transfer

3rd byte

to

6th byte

Version management information

(

See

Table 3.4.10)

7th byte

Frequency information

8th byte

9th byte

Baud rate modification command
(

See

Table 3.4.8

.

)

9600 bps


OK: Echo back data

Error: Error code x 3

10th byte

to

(n

− 4)th byte

User program

Intel Hex format (binary)

NG: Operation stop by checksum error

(n

− 3)th byte

OK: SUM (High)

(See (4)-c).)

(n

− 2)th byte

OK: SUM (Low)

Boot

ROM

(n

− 1)th byte

n’th byte

User program start command (C0H)
(See Table 3.4.9.)


New baud rate


OK: Echo back data (C0H)

Error: Error code x 3

RAM

Branch to user program start address

“Error code x 3” means that the error code is transmitted three times. For example, if the error code is 62H, the

TMP92CZ26A transmits 62H three times. For error codes, see (4)-b).