92CZ26A-49

(2) I/O register settings

Table 3.4.5 shows the I/O registers that are set by the boot program.
After the boot sequence, if execution moves to an application system program

without a reset being asserted, the settings of these I/O registers must be taken into
account. Also note that the registers in the CPU and the internal RAM remain in the
state after execution of the boot program.

Table 3.4.5 I/O Register Settings by Boot Program

Register Name Set Value

Description

WDMOD

00H

Watchdog timer not active

WDCR

B1H

Watchdog timer disabled

SYSCR0

70H

High-frequency and low-frequency oscillators operating

SYSCR1

00H

Clock gear = 1/1

SYSCR2 2CH

Initial

value

PLLCR0

00H

PLL clock not used

PLLCR1 00H

or

60H

Normally PLL is disabled.

However, only in the case of booting via USB, PLL is
activated for USB.

INTEUSB

04H

USB interrupt level setting

INTETC01

44H

INTTC interrupt level setting

Note:

The values to be set in the I/O registers for

UART and USB are not described here. If these functions are

needed in a user program, set each I/O register as necessary.